EXPERIMENT DATA ACCOMPANYING THIS BOOK

In this experiment, Electrical Geodesic Inc. (EGI) HydroCel Geodesic Sensor Net with 128-channel EEG device was employed for EEG recording. The net was prepared with saline electrolyte to minimize impedance and improve quality of signals. In the recording, 250 samples per second was used as the sampling rate. The EEG raw data was recorded and stored on the hard disk drive as backup for further analysis. A notch filter was used to remove line noise of 50 Hz. Average referencing was used during the recoding.

EEG, ECG, and SSQ data for one subject are provided with this book in a separate directory. To access these files, please go to the directory BookDataChap10 in the data files accompanying this book. The details of these files are provided in Table 10.1. For the complete dataset of 42 subjects, please contact the authors at This email address is being protected from spam bots, you need Javascript enabled to view it

RELEVANT PAPERS

This section provides a list of some of the papers that have utilized the data acquired from the experiment described in this chapter. The

Table 10.1 EEG and ECG data description S. No. Directory name Description

S. No.

Directory name

Description

01

Eyesclosed

This directory contains eyes-closed EEG or ECG 5 minutes resting state recording of one participant.

The name is “EC” and it is in .mat file format. The EEG and ECG data are provided in separate directories.

02

Eyesopen

This directory contains eyes-open EEG or ECG 5 minutes resting state recording of one participant.

The name is “EO” and it is in .mat file format. The EEG and ECG data are provided in separate directories.

03

VIMS

This directory contains 10 minutes EEG or ECG recording during watching the movie with VIMS stimuli. The EEG and ECG data are provided in separate directories.

04

SSQ

This directory contains the SSQ responses of one subject recording via questionnaire and saved as an Excel spreadsheet.

Computing SSQ grades:There are total items 1—16 (scale of 0—3) in the SSQ. Nausea (items 1, 6, 7, 8, 9, 15, 16), Oculomotor (items 1 to 5, 9, and 11), and Disorientation (items 5, 8, and 10—14).

Scale multiplication factor: Nausea: A = score X 9.54; Oculomotor: B = score X 7.58; Disorientation:

C = score X 13.92; Total SSQ score = (A + B + C) X 3.74

following papers should be cited when using the experiment design or the

data provided with this chapter.

  • 1. Naqvi SAA, Badruddin N, Jatoi MA, Malik AS, Hazabbah W Abdullah B. EEG based time and frequency dynamics analysis of visually induced motion sickness (VIMS). Australas Phys Eng Sci Med. 2015;38: 721-729.
  • 2. Naqvi SAA, Badruddin N, Malik AS, Hazabbah W, Abdullah B. Does 3D produce more symptoms of visually induced motion sickness? In: Engineering in Medicine and Biology Society (EMBC), 2013 35th Annual International Conference of the IEEE, 2013;pp. 6405-6408.
 
Source
< Prev   CONTENTS   Source   Next >